JAAOS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Am Acad Orthop Surg, Vol 10, No 4, July/August 2002, 233-238.
© 2002 the American Academy of Orthopaedic Surgeons

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lachiewicz, P. F.
Right arrow Articles by Kelley, S. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lachiewicz, P. F.
Right arrow Articles by Kelley, S. S.

The Use of Constrained Components in Total Hip Arthroplasty

Paul F. Lachiewicz, MD and Scott S. Kelley, MD

Dr. Lachiewicz is Professor, Department of Orthopaedics, University of North Carolina at Chapel Hill, Chapel Hill, NC. Dr. Kelley is Associate Professor, Department of Orthopaedics, University of North Carolina at Chapel Hill, Chapel Hill.

Reprint requests: Dr. Lachiewicz, 242 Burnett-Womack Building, CB 7055, Chapel Hill, NC 27599.

The use of a constrained component may be appropriate for the surgical treatment of recurrent dislocation due to soft-tissue insufficiency following a total hip arthroplasty. Constrained components usually include a locking mechanism incorporated into the polyethylene acetabular liner to keep the prosthetic femoral head in place. Two different prosthetic designs are available and have been approved by the U.S. Food and Drug Administration. The S-ROM constrained component uses additional polyethylene in the rim, which deforms to more fully capture the femoral head and then is held in place by a metal locking ring. The Howmedica Osteonics constrained component is a tripolar device; its bipolar component articulates with another polyethylene liner. These constrained components transfer hip forces that would otherwise lead to dislocation to the locking mechanism, the liner-shell interface, or the bone-prosthesis interface. These forces may eventually contribute to failure of the component due to loosening, dissociation, breakage, or recurrent dislocation. Studies of these components show a failure rate of 4% to 29% at relatively short-term follow-up.




This article has been cited by other articles:


Home page
J Bone Joint Surg BrHome page
R. J. K. Khan, D. Fick, R. Alakeson, S. Haebich, M. de Cruz, B. Nivbrant, and D. Wood
A constrained acetabular component for recurrent dislocation
J Bone Joint Surg Br, July 1, 2006; 88-B(7): 870 - 876.