Rush-Presbyterian-St. Luke's Medical Center, Chicago.
In vivo degradation of prosthetic implant materials is increasingly recognized as a major factor limiting the durability of total joint arthroplasty. In vivo degradation occurs primarily by means of wear processes that can generate large quantities of particulate debris. This debris can stimulate an adverse local host response leading to periprosthetic bone loss, which can compromise implant fixation and bone stock. The authors review the basic mechanisms of implant degradation and the host response to particulate degradation products, particularly in the context of the pathogenesis of osteolysis. Submicron polyethylene particles (mean size, 0.5 um) are the dominant type of wear particle present in periprosthetic tissues associated with uncemented hip replacements. Polyethylene wear can be minimized by improving the quality of the polyethylene, avoiding use of large-diameter (greater than 28 mm) femoral heads in total hip arthroplasty, and improving the design and fabrication of modular connections, which can be important sources of three-body wear particles. Advances in the understanding of the basic mechanisms of osteolysis are critical to the development of preventive measures that will minimize the clinical impact of this phenomenon.
This article has been cited by other articles:
![]() |
K. W. Nam, J. J. Yoo, Y. Lae Kim, Y.-M. Kim, M.-H. Lee, and H. J. Kim Alumina-Debris-Induced Osteolysis in Contemporary Alumina-on-Alumina Total Hip Arthroplasty. A Case Report J. Bone Joint Surg. Am., November 1, 2007; 89(11): 2499 - 2503. [Full Text] [PDF] |
||||
![]() |
M. W. Hanna and T. S. Thornhill Thigh Mass and Lytic Diaphyseal Femoral Lesion Associated with Polyethylene Wear After Hybrid Total Knee Arthroplasty. A Case Report J. Bone Joint Surg. Am., November 1, 2006; 88(11): 2473 - 2478. [Full Text] [PDF] |
||||
![]() |
J. J. Yoo, Y.-M. Kim, K. S. Yoon, K.-H. Koo, W. S. Song, and H. J. Kim Alumina-on-Alumina Total Hip Arthroplasty. A Five-Year Minimum Follow-up Study J. Bone Joint Surg. Am., March 1, 2005; 87(3): 530 - 535. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. Yoo, H. J. Kim, and Y.-M. Kim Damage of an Alumina-on-Alumina Bearing Surface from a Difficult Reduction of a Total Hip Arthroplasty. A Report of Three Cases J. Bone Joint Surg. Am., February 1, 2004; 86(2): 376 - 378. [Full Text] [PDF] |
||||
![]() |
R. A. Butler and R. L. Barrack Total Hip Wear Debris Presenting as Lower Extremity Swelling. A Report of Two Cases J. Bone Joint Surg. Am., January 1, 2004; 86(1): 142 - 145. [Full Text] [PDF] |
||||
![]() |
E. Grimaud, L. Soubigou, S. Couillaud, P. Coipeau, A. Moreau, N. Passuti, F. Gouin, F. Redini, and D. Heymann Receptor Activator of Nuclear Factor {kappa}B Ligand (RANKL)/Osteoprotegerin (OPG) Ratio Is Increased in Severe Osteolysis Am. J. Pathol., November 1, 2003; 163(5): 2021 - 2031. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Illgen II and H. E. Rubash The Optimal Fixation of the Cementless Acetabular Component in Primary Total Hip Arthroplasty J. Am. Acad. Ortho. Surg., January 1, 2002; 10(1): 43 - 56. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Urban, K. L. Garvin, C. K. Boese, L. Bryson, D. R. Pedersen, J. J. Callaghan, and R. K. Miller Ceramic-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty : Seventeen to Twenty-one-Year Results J. Bone Joint Surg. Am., November 1, 2001; 83(11): 1688 - 1694. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. F. Pollice, R. N. Rosier, R. J. Looney, J. E. Puzas, E. M. Schwarz, and R. J. O'Keefe Oral Pentoxifylline Inhibits Release of Tumor Necrosis Factor-Alpha from Human Peripheral Blood Monocytes : A Potential Treatment for Aseptic Loosening of Total Joint Components J. Bone Joint Surg. Am., July 1, 2001; 83(7): 1057 - 1061. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Vermes, R. Chandrasekaran, J. J. Jacobs, J. O. Galante, K. A. Roebuck, and T. T. Glant The Effects of Particulate Wear Debris, Cytokines, and Growth Factors on the Functions of MG-63 Osteoblasts J. Bone Joint Surg. Am., February 1, 2001; 83(2): 201 - 201. [Abstract] [Full Text] |
||||
![]() |
D. T. Felson, R. C. Lawrence, M. C. Hochberg, T. McAlindon, P. A. Dieppe, M. A. Minor, S. N. Blair, B. M. Berman, J. F. Fries, M. Weinberger, et al. Osteoarthritis: New Insights. Part 2: Treatment Approaches Ann Intern Med, November 7, 2000; 133(9): 726 - 737. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-W. Xu, J. Ma, T.-F. Li, E. Waris, A. Alberty, S. Santavirta, and Y. T Konttinen Expression of epidermal growth factor and transforming growth factor alpha in interfacial membranes retrieved at revision total hip arthroplasty Ann Rheum Dis, October 1, 2000; 59(10): 822 - 827. [Abstract] [Full Text] |
||||
![]() |
J. J. JACOBS, A. K. SKIPOR, L. M. PATTERSON, N. J. HALLAB, W. G. PAPROSKY, J. BLACK, and J. O. GALANTE Metal Release in Patients Who Have Had a Primary Total Hip Arthroplasty. A Prospective, Controlled, Longitudinal Study J. Bone Joint Surg. Am., October 1, 1998; 80(10): 1447 - 58. [Abstract] [Full Text] |
||||
![]() |
T. A. BLAINE, P. F. POLLICE, R. N. ROSIER, P. R. REYNOLDS, J. E. PUZAS, and R. J. O'KEEFE Modulation of the Production of Cytokines in Titanium-Stimulated Human Peripheral Blood Monocytes by Pharmacological Agents. The Role of cAMP-Mediated Signaling Mechanisms*{{dagger}} J. Bone Joint Surg. Am., October 1, 1997; 79(10): 1519 - 28. [Abstract] [Full Text] |
||||
![]() |
D. R. DIDUCH, J. N. INSALL, W. N. SCOTT, G. R. SCUDERI, and D. FONT-RODRIGUEZ Total Knee Replacement in Young, Active Patients. Long-Term Follow-up and Functional Outcome J. Bone Joint Surg. Am., April 1, 1997; 79(4): 575 - 82. [Abstract] [Full Text] |
||||
![]() |
G. S. TOMPKINS, J. J. JACOBS, L. R. KULL, A. G. ROSENBERG, and J. O. GALANTE Primary Total Hip Arthroplasty with a Porous-Coated Acetabular Component. Seven-to-Ten-Year Results J. Bone Joint Surg. Am., February 1, 1997; 79(2): 169 - 76. [Abstract] [Full Text] |
||||
![]() |
C. J. SYCHTERZ, K. H. MOON, Y. HASHIMOTO, K. M. TEREFENKO, C. A. ENGH JR., and T. W. BAUER Wear of Polyethylene Cups in Total Hip Arthroplasty. A Study of Specimens Retrieved Post Mortem J. Bone Joint Surg. Am., August 1, 1996; 78(8): 1193 - 1200. [Abstract] [Full Text] |
||||
![]() |
R. M. URBAN, J. J. JACOBS, D. R. SUMNER, C. L. PETERS, F. R. VOSS, and J. O. GALANTE The Bone-Implant Interface of Femoral Stems with Non-Circumferential Porous Coating. A Study of Specimens Retrieved at Autopsy J. Bone Joint Surg. Am., July 1, 1996; 78(7): 1068 - 81. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |